- Year Built1972
- Square Footage2,436
- Replacement Cost$1,416,329
- Condition Budget$647,032
- Facility Condition Index55%
Condition Assessment
System Rating ScoreGood
Fair
(or will require attention in near future 3-10 years)
Poor
(or will require attention now 0-2 years)
Exterior
Fair
Exterior Structure: Replace damaged decorative metal perimeter panels, sealants and fasteners and paint. Clean and repaint exterior CMU blocks; replace any deteriorated mortar at the time of refinishing. Replace all building seam calking.
Good
Foundation: No issues observed.
Good
Parking/Traffic: Information included with the HS Dashboard information.
Good
Site: Add additional perimeter lighting adjacent to entry points.
Good
Doors: Paint exterior metal doors and replace deteriorated weather stripping and door hardware.
Good
Roof: Installed in 2020 the single ply roof system is in overall good condition. Manufacturer-recommended maintenance should be implemented.
Interior
Good
Interior Structure: Paint interior CMU walls where finish had deteriorated. Replace damaged and stained ceiling tiles.
Good
Plumbing: No issues observed. Plumbing systems 30 years or older should be inspected and repaired or replaced as inspection dictates.
Good
ADA: No issues observed.
Good
Furnishing, Fixtures, Equipment: No issues observed.
Good
Electrical: Update lighting to LED units. Electrical systems 30 years or older should be inspected and repaired or replaced as inspection dictates.
Poor
Safety/Security: Install sprinkler system in all student-occupied areas. Systems 30 years or older should be inspected and repaired or replaced as inspection dictates.
Good
Flooring: No issues observed.
Good
HVAC: HVAC units are in good condition and less than 5 years of age. Preventative maintenance should be implemented.
Priority Projects
- Clean and repaint exterior CMU blocks; replace any deteriorated mortar at the time of refinishing. Replace all building seam calking.
Additional Projects, if Funds Become Available
- Metal panels on perimeter are original to the facility and should have repairs and replacements completed to ensure further deterioration.
- Replace damaged decorative metal perimeter panels, sealants and fasteners and paint.
- Paint exterior metal doors and replace deteriorated weather stripping and door hardware.
- Paint interior CMU where finish had deteriorated.
- Replace damaged and stained ceiling tiles.
Actions to Improve the Educational Environment
No applicable at this facility.