Seagraves ISD - High School-Stadium
- Year Built1969
- Square Footage3,524
- Replacement Cost$4,514,470
- Condition Budget$2,527,549
- Facility Condition Index80%
Condition Assessment
System Rating ScoreGood
Fair
(or will require attention in near future 3-10 years)
Poor
(or will require attention now 0-2 years)
Exterior
Fair
Exterior Structure: Re-seal the building envelope by regrouting or repointing the masonry work and replacing cracking or missing expansion joint caulking as needed. Check fasteners and flashings for tightness and seal; re-caulk door and window frames as needed. Seal all openings between walls and roof.
Fair
Foundation: Re-seal minor slab cracking and masonry wall cracking, indicating movement, observe repairs for additional movement.
Promote stable soil conditions around foundation by creating positive storm water drainage away from structure and eliminating standing water next to foundation.
Fair
Parking/Traffic: Repair any damage to roadways and parking, slurry coat asphalt surfaces, re-striping all parking, ADA hashmarks.
Poor
Site: Replace existing, damaged and broken asphalt surfaces with hard surface paving. Replace or repair ADA ramps in bleacher areas on both sides. Seal large cracks in concrete surfaces and repair uneven surfaces to prevent trip hazards. Repair unsecured area of perimeter fence near elementary school. Recommend inspection of facility after dark and installing additional lighting in any non-lit areas or dark corners under bleachers.
Fair
Doors: Replace weatherstripping and door sweeps on exterior doors as needed. Replace non-functioning doors and hardware as needed for proper operation. Update door hardware using a district master restricted keyway system, patch holes, and refresh finish surfaces. Refresh exterior door finished surfaces as needed. Repair or replace damaged, weakened, and delaminating interior doors.
Fair
Exterior/Interior Windows: Replace broken glass on single pane windows, replace water damaged frames and recaulk to prevent further damage.
Poor
Roof: Roof assessment was made by visual observation from the interior building condition and what could be seen of the roof from the ground. It is assumed that all roofing materials are original to the buildings, making several of the roofs at or past their useful life expectancy. Home press box has a roof access hatch and the roof has visible deterioration of surface, as well as visible leaks on interior ceiling. Home and visitor restrooms have visible leaks, and the exterior building envelope is in poor condition. Concession roof have gaps between roof & wall where water and pest intrusions could occur. No visible signs of interior leaks. Due to recent hail event, district is recommend to seek an inspection by licensed roofing contractor to determine extent of repairs or need for replacement of these roofs.
Interior
Fair
Interior Structure: Repair or replace masonry wall structure on restrooms as needed to support loading and finish surfacing. Repair or replace damaged or missing masonry wall units and re-grout closing all openings where needed. Repair or replace damaged sheetrock. Refresh finished surfaces. Replace wood paneling in visitors press box. Refresh high touched interior wall finished surfaces. Deep clean, repair vinyl paneling, re-seal any loose edges. Repair water damaged sheetrock and refresh finish as needed. Replace damaged and stained ceiling tiles as needed. Have glued-in tiles in visitor box tested for asbestos before removal. Replace aged and water damaged insulation panels in restrooms.
Poor
ADA: ADA accessibility is limited at stadium. Improvements are needed to restrooms, common area hard surfaces, and ADA ramps to bleachers.
Fair
Furnishing, Fixtures, Equipment: Ice maker is leaking in the concession area. Repair food prep area. Update restroom accessories and stalls for ADA compliance as needed. Replace damaged counters in ticket booths and visitor's press box Replace damaged moveable furnishings as needed.
Fair
Electrical: Mechanical systems 30 years or older should be inspected and repaired or replaced as inspection dictates. Install lighting control system.
Poor
Safety/Security: Review and consider Safety & Security Recommendations on the Facility Details page.
Fair
Flooring: Deep clean, repair damaged soft surface flooring. Replace aged and damaged resilient tile flooring. Have VCT in visitors press box tested for asbestos before removing. Repair and re-seal cracks in concrete floor, repair or replace finish surfacing, observe for movement. Deep clean, repair or replace ceramic tile flooring, re-grout, and re-seal surface.
Fair
HVAC: Plan for replacement of HVAC units that will be at or past their useful life expectancy in 2025 & 2027. Recommend installation of window AC unit in visitor press box. Plan for replacement of furnace units that will be at or past their useful life expectancy in 2025 & 2027.
Priority Projects
- Repair or replace the leaking roof systems on both press boxes and restrooms.
- Determine best course of action for aged and non-compliant restrooms, renovation or rebuild.
- Replace existing, damaged and broken asphalt surfaces with hard surface paving to prevent trip hazards.
- Replace or repair ADA ramps in bleacher areas on both sides.
- Review Safety and Security recommendations and perform security improvements.
Additional Projects, if Funds Become Available
- Demolish and rebuild restrooms on both sides of the field.
- Add interior and exterior directional signage, ADA compliant parking signage and ADA compliant room signage.
- Recommend compliant landings on all entrance and exit doors.
- Replace nets and backboards at tennis court.
- Repair or resurface tennis courts as needed.
- Water heater in concession has exceeded useful life expectancy. Plan for replacement.
- Re-seal the building envelope and seal all openings between walls and roof.
- Repair and repaint all interior walls as needed in all structures.
- Reseal minor slab cracking at concession and divert water away from building.
- Plan for proactive HVAC replacement in 2025 & 2027.
- Renovate visitor press box and sample for asbestos in floor and ceiling tile.
- Install a window AC unit in visitor press box.
- Resurface and restripe parking areas.
- Have mechanical, electrical and plumbing infrastructure over 30 years old, inspected, repaired or replaced as needed.
- Deep clean, repair or replace soft surface flooring or resilient tile as needed.
Educational Adequacy Assessment
System Rating ScoreAdequate Spaces
Needs Improvement
Not Adequate
Poor
Security: See Safety & Security recommendations on the Facility Details page.